Hemodynamic monitor
MostCare Up
Description
To have more information about our complete offer for hemodynamic management, please visit our dedicated website. MostCareUp is the only monitor… Read more
Indication
Please refer to the MostCare Up user manual.
Product highlights
- High Accuracy arterial variables:
- Dynamic e-filter
- PRAM patented algorithm
- More than 70 clinical studies - Best quality/price ratio:
- No dedicated disposable
- Unlimited patient use - Plug&play
- Set-up in 60 seconds
- No calibration required
Description
To have more information about our complete offer for hemodynamic management, please visit our dedicated website.MostCareUp is the only monitor able to follow in real time and from beat to beat even the slightest hemodynamic variations in the patient. Thanks to the patented algorithm based on the PRAM method (Pressure Recording Analytical Method), MostCareUp evaluates cardiac output and many other hemodynamic parameters without any prior calibration and in a totally operator-independent way, applicable therefore to each type of patient both in stable and highly unstable hemodynamic conditions. An immediate, customisable interface can display a broad set of information regarding the preload, afterload, cardiac contractility and efficiency, which have become vitally important elements in optimising the treatment of high-risk patients and in defining the best hemodynamic settings for patients with alterations in their cardiovascular systems. MostCareUp can display trends for many hemodynamic variables simultaneously. It is also possible to insert personalised markers during specific events (e.g. start treatment). The do&check function is designed specifically to help the clinic when monitoring hemodynamic variations following specific treatments (e.g. fluid challenge).
In summary, the main technical characteristics of this instrument are:
- 1000Hz sampling of the blood pressure waveform
- Beat-to-beat analytical process of the entire blood pressure waveform (both systolic and diastolic phase)
- The use of an unique and patented method (P.R.A.M.) for the evaluation of Cardiac Output and cardiovascular efficiency
- An exclusive (patented) dynamic filter to reduce the resonance artifacts and to optimize the quality of the arterial blood pressure signal
- No need of any kind of initial calibration (eg. cold bolus injection for the thermodilution) or additional maneuver to calibrate the algorithm
- No dedicated disposable: compatible with any arterial catheter and blood pressure transducer in the market
- Value of the dicrotic pressure exclusively measured and visualised in the display beat by beat
- Displaying of systemic variables (systolic pressure, diastolic pressure, mean pressure and heart rate), standard hemodynamic variables (cardiac output, stroke volume, systemic vascular resistance, dynamic fluid responsiveness variables, oxygen delivery, dP/dtmax as an index of contractility) and exclusively determined hemodynamic variables (dicrotic pressure, CCE as an index of efficiency and cardiovascular coupling)
- In particular, the Cardiac Cycle Efficiency (CCE) is an exclusive variable of MostCare®: it is the only hemodynamic parameter which identifies the level of energy expenditure of the cardiovascular system, providing information on the evolution of the clinical condition of the patients and on the effectiveness of therapies. It has been verified a direct correlation of the CCE with the left ventricle ejection fraction and an inverse correlation with the pro-BNP.
- Validation in the widest range of clinical conditions, including paediatric, septic, trauma, IABP and cardiology patients.
References and Features
Packaging | |||
---|---|---|---|
Favourites | Code | Units/Box | Units/Case |
08MC0202E0V | 1 | 1 | |
08MC0255E0V | 1 | 1 |
Additional information
-
Contains Latex No
-
Contains animal product No
-
Pyrogen-free No
Documentation
-
Mostcare Up Clinical Applications guide
-
Brochure Mostcare Up variables rev. 2
-
Brochure MostCare
-
Instructions for use