Description
WOVEN POLYESTER VASCULAR GRAFT Wide range of grafts designed for aortic root surgery. Equidistant longitudinal guide lines, at 120° angles. … Read more
Indication
POLYTHESE® IC / ICT / 3GL vascular grafts are intended for use in patients whose medical conditions require open-surgical vascular repair, and who do not have any contraindications.
Medical conditions that may indicate thoracic, abdominal or peripheral open-surgical vascular repair with implantation of a vascular graft include:
. Peripheral arterial diseases (PAD), characterised by reduced blood flow to the lower extremities – arterial occlusive disease,
. Arterial aneurysms, characterised by a permanent localised (i.e., focal) dilation with an increase in diameter of at least a 50%,
. Arterial dissection, characterised by an abnormal, and usually abrupt, formation of a tear along the inside wall of an artery.
Their indications are limited to thoracic, abdominal and peripheral vascular repair surgery not crossing the knee flexion crease.
Vessel characteristics:
POLYTHESE® IC / ICT / 3GL vascular grafts are intended to replace and/or bypass arteries with diameters ≥ 6 mm and ≤ 38 mm in the following locations:
. Thoracic aorta (ascending and/or descending) and/or aortic arch and/or thoraco-abdominal aorta
. Abdominal aortic and/or aorto-iliac and/or aorto-femoral
. Peripheral arteries (above the knee)
Product highlights
Designed for a better positionning on the aortic valve thanks to the 3 guide lines
Without carcinogenic agents
Type 1 bovine collagen
No formaldehyde nor glutaraldehyde included during manufacturing
OEKO TEX thread
Environmentally friendly
Description
WOVEN POLYESTER VASCULAR GRAFT- Wide range of grafts designed for aortic root surgery.
- Equidistant longitudinal guide lines, at 120° angles.
Features & benefits:
Dimensional stability
- Good resistance to circumferential dilatation (1)
Patented technology of impregnation (collagen cxe®)
- Formaldehyde and Glutaraldehyde Free (2)
External velvet-like surface: support for neighbour tissues attachment and periprosthetic encapsulation
Smooth and texturized endoluminal wall: support for pseudo-intimal cells ingrowth
(1) Rapport RRD-0101-01 rev00 - 29/10/2012.
(2) LNE certificate n°F014288 (2005): analysis of Perouse Grafts: formaldehyde free and glutaraldehyde free.
References and Features
Packaging | |||
---|---|---|---|
Favourites | Code | Units/Box | Units/Case |
PT3GL020015 | 1 | 1 | |
PT3GL020030 | 1 | 1 | |
PT3GL020060 | 1 | 1 | |
PT3GL022015 | 1 | 1 | |
PT3GL022030 | 1 | 1 | |
PT3GL022060 | 1 | 1 | |
PT3GL024015 | 1 | 1 | |
PT3GL024030 | 1 | 1 | |
PT3GL024060 | 1 | 1 | |
PT3GL026015 | 1 | 1 | |
PT3GL026030 | 1 | 1 | |
PT3GL026060 | 1 | 1 | |
PT3GL028015 | 1 | 1 | |
PT3GL028030 | 1 | 1 | |
PT3GL028060 | 1 | 1 | |
PT3GL030015 | 1 | 1 | |
PT3GL030030 | 1 | 1 | |
PT3GL030060 | 1 | 1 | |
PT3GL032015 | 1 | 1 | |
PT3GL032030 | 1 | 1 | |
PT3GL032060 | 1 | 1 | |
PT3GL034015 | 1 | 1 | |
PT3GL034030 | 1 | 1 | |
PT3GL034060 | 1 | 1 | |
PT3GL036030 | 1 | 1 | |
PT3GL036060 | 1 | 1 | |
PT3GL038015 | 1 | 1 | |
PT3GL038030 | 1 | 1 | |
PT3GL038060 | 1 | 1 |
Additional information
-
Contains Latex No
-
Contains animal product Yes
-
Pyrogen-free Yes
Documentation
-
Brochure Polythese IC-3GL
-
Catalogue Cardiovascular sterile - 01/2023
-
Instructions for use